Please use this identifier to cite or link to this item: https://cuir.car.chula.ac.th/handle/123456789/77759
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorThumnoon Nhujak-
dc.contributor.authorParinya Seelanan-
dc.contributor.otherChulalongkorn University. Faculty of Science-
dc.date.accessioned2021-11-11T10:30:55Z-
dc.date.available2021-11-11T10:30:55Z-
dc.date.issued2005-
dc.identifier.issn9745326631-
dc.identifier.urihttp://cuir.car.chula.ac.th/handle/123456789/77759-
dc.description.abstractMicroemulsion electrokinetic chromatography (MEEKC) was developed for quantitative analysis of avermectins, such as abamectin, doramectin and ivermectin, in commercial formulations, using the microemulsion buffer containing a 50 mm phosphate buffer at pH 2.5, 1.1 % v/v n-octane as oil droplets, 180 mM sodium dodecyl sulfate as surfactant, 890 mM 1-butanol as co-surfactant and 30 % v/v ethanol as organic co-solvent; applied voltage of -15 kV; and separation temperature at 25 °C. Achieved baseline resolution up to 4.9 was obtained with analysis time within 25 min. High accuracy and precision of the method were obtained. The developed MEEKC method was used for quantitative analysis of avermectins in commercial formulations. The contents of avermectins in commercial formulations determined by MEEKC were found to be insignificantly different with those determined by high performance liquid chromatography (HPLC). Therefore, MEEKC can be used as an alternative method to HPLC for quantitative determination of avermectins with shorter analysis time and lower amount of organic solvent-
dc.description.abstractalternativey Microemulsion electrokinetic chromatography (MEEKC) was developed for quantitative analysis of avermectins, such as abamectin, doramectin and ivermectin, in commercial formulations, using the microemulsion buffer containing a 50 mm phosphate buffer at pH 2.5, 1.1 % v/v n-octane as oil droplets, 180 mM sodium dodecyl sulfate as surfactant, 890 mM 1-butanol as co-surfactant and 30 % v/v ethanol as organic co-solvent; applied voltage of -15 kV; and separation temperature at 25 °C. Achieved baseline resolution up to 4.9 was obtained with analysis time within 25 min. High accuracy and precision of the method were obtained. The developed MEEKC method was used for quantitative analysis of avermectins in commercial formulations. The contents of avermectins in commercial formulations determined by MEEKC were found to be insignificantly different with those determined by high performance liquid chromatography (HPLC). Therefore, MEEKC can be used as an alternative method to HPLC for quantitative determination of avermectins with shorter analysis time and lower amount of organic solvent-
dc.language.isothen_US
dc.publisherChulalongkorn University.en_US
dc.relation.urihttp://doi.org/10.14457/CU.the.2005.1935-
dc.rightsChulalongkorn Universityen_US
dc.subjectMicroemulsion electrokinetic chromatographyen_US
dc.subjectAvermectins macrocyclic lactones -- Analysisen_US
dc.subjectOrganic solventsen_US
dc.subjectไมโครอิมัลชันโทรไคเนทิกโครมาโทกราฟีen_US
dc.subjectอะเวอร์เมกทินแมกโครไซคลิกแลกโทน -- การวิเคราะห์en_US
dc.subjectสารตัวทำละลายอินทรีย์en_US
dc.titleMicroemulsion electrokinetic chromatography for separation and analysis of avermectin macrocyclic lactonesen_US
dc.title.alternativeไมโครอิมัลชันโทรไคเนทิกโครมาโทกราฟีสำหรับการแยกและการวิเคราะห์อะเวอร์เมกทินแมกโครไซคลิกแลกโทนen_US
dc.typeThesisen_US
dc.degree.nameMaster of Scienceen_US
dc.degree.levelMaster's Degreeen_US
dc.degree.disciplineChemistryen_US
dc.degree.grantorChulalongkorn Universityen_US
dc.identifier.DOI10.14457/CU.the.2005.1935-
Appears in Collections:Grad - Theses

Files in This Item:
File Description SizeFormat 
Parinya_se_front_p.pdfCover and abstract1.07 MBAdobe PDFView/Open
Parinya_se_ch1_p.pdfChapter 1752.93 kBAdobe PDFView/Open
Parinya_se_ch2_p.pdfChapter 21.35 MBAdobe PDFView/Open
Parinya_se_ch3_p.pdfChapter 3786.67 kBAdobe PDFView/Open
Parinya_se_ch4_p.pdfChapter 41.83 MBAdobe PDFView/Open
Parinya_se_ch5_p.pdfChapter 5644.25 kBAdobe PDFView/Open
Parinya_se_back_p.pdfReference and appendix754.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.