DSpace Repository

Accuracy of liver volume measurement using multidetector computed tomography

Show simple item record

dc.contributor.author Natthaporn Tanpowpong
dc.contributor.author Sudarat Yimpraphan
dc.contributor.author Laddawan Vajragupta
dc.contributor.author Boonchu Sirijindakul
dc.contributor.author Bunthoon Nunthasoot
dc.contributor.other Chulalongkorn University. Department of Radiology
dc.contributor.other Chulalongkorn University. Department of Radiology
dc.contributor.other Chulalongkorn University. Faculty of Medicine
dc.contributor.other Chulalongkorn University. Department of Surgery
dc.contributor.other Chulalongkorn University. Department of Surgery
dc.date.accessioned 2012-03-08T03:14:11Z
dc.date.available 2012-03-08T03:14:11Z
dc.date.issued 2007
dc.identifier.citation Asian biomedicine : research, reviews and news. 1,4(December 2007): 415-420 en
dc.identifier.issn 1905-7415
dc.identifier.uri http://cuir.car.chula.ac.th/handle/123456789/17485
dc.description.abstract Background: Measurement of liver volume has been used in planning radiotherapy dosimetry, assessing the progressiveness of various diseases and measuring the response to treatment. Objective: To measure liver volume using multidetector computed tomography (MDCT), and to evaluate the accuracy and inter-observer reliability of liver volume measurement using MDCT. Methods: Measurements were done using a track-ball to draw its outline manually, and calculate by summation of each slice volume which was measured in 8 mm thickness. The calculated liver volume was compared to the actual liver volume which was measured by water replacement. Results and conclusion: There was a strong correlation between the calculated and actual liver volumes performed by a radiologist and a technician (98.0 % and 97.1 % agreement, respectively). High observer reliability was identified (99.2 % agreement). This technique can be easily used by well-trained personnel such as radiologists or technicians. en
dc.format.extent 301610 bytes
dc.format.mimetype application/pdf
dc.language.iso en es
dc.publisher Chulalongkorn University en
dc.rights Chulalongkorn University en
dc.subject Liver en
dc.subject Tomography en
dc.title Accuracy of liver volume measurement using multidetector computed tomography en
dc.type Article es
dc.email.author No information provided
dc.email.author No information provided
dc.email.author No information provided
dc.email.author No information provided
dc.email.author Bunthoon.N@Chula.ac.th
dc.subject.keyword Liver volume en
dc.subject.keyword Measurement en


Files in this item

This item appears in the following Collection(s)