dc.contributor.author |
Natthaporn Tanpowpong |
|
dc.contributor.author |
Sudarat Yimpraphan |
|
dc.contributor.author |
Laddawan Vajragupta |
|
dc.contributor.author |
Boonchu Sirijindakul |
|
dc.contributor.author |
Bunthoon Nunthasoot |
|
dc.contributor.other |
Chulalongkorn University. Department of Radiology |
|
dc.contributor.other |
Chulalongkorn University. Department of Radiology |
|
dc.contributor.other |
Chulalongkorn University. Faculty of Medicine |
|
dc.contributor.other |
Chulalongkorn University. Department of Surgery |
|
dc.contributor.other |
Chulalongkorn University. Department of Surgery |
|
dc.date.accessioned |
2012-03-08T03:14:11Z |
|
dc.date.available |
2012-03-08T03:14:11Z |
|
dc.date.issued |
2007 |
|
dc.identifier.citation |
Asian biomedicine : research, reviews and news. 1,4(December 2007): 415-420 |
en |
dc.identifier.issn |
1905-7415 |
|
dc.identifier.uri |
http://cuir.car.chula.ac.th/handle/123456789/17485 |
|
dc.description.abstract |
Background: Measurement of liver volume has been used in planning radiotherapy dosimetry, assessing the progressiveness of various diseases and measuring the response to treatment. Objective: To measure liver volume using multidetector computed tomography (MDCT), and to evaluate the accuracy and inter-observer reliability of liver volume measurement using MDCT. Methods: Measurements were done using a track-ball to draw its outline manually, and calculate by summation of each slice volume which was measured in 8 mm thickness. The calculated liver volume was compared to the actual liver volume which was measured by water replacement. Results and conclusion: There was a strong correlation between the calculated and actual liver volumes performed by a radiologist and a technician (98.0 % and 97.1 % agreement, respectively). High observer reliability was identified (99.2 % agreement). This technique can be easily used by well-trained personnel such as radiologists or technicians. |
en |
dc.format.extent |
301610 bytes |
|
dc.format.mimetype |
application/pdf |
|
dc.language.iso |
en |
es |
dc.publisher |
Chulalongkorn University |
en |
dc.rights |
Chulalongkorn University |
en |
dc.subject |
Liver |
en |
dc.subject |
Tomography |
en |
dc.title |
Accuracy of liver volume measurement using multidetector computed tomography |
en |
dc.type |
Article |
es |
dc.email.author |
No information provided |
|
dc.email.author |
No information provided |
|
dc.email.author |
No information provided |
|
dc.email.author |
No information provided |
|
dc.email.author |
Bunthoon.N@Chula.ac.th |
|
dc.subject.keyword |
Liver volume |
en |
dc.subject.keyword |
Measurement |
en |