Please use this identifier to cite or link to this item: https://cuir.car.chula.ac.th/handle/123456789/75131
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorOrawon Chailapakul-
dc.contributor.advisorLuxsana Dubas-
dc.contributor.authorSarawadee Korsrisakul-
dc.contributor.otherChulalongkorn University. Faculty of Science-
dc.date.accessioned2021-08-26T04:00:25Z-
dc.date.available2021-08-26T04:00:25Z-
dc.date.issued2006-
dc.identifier.urihttp://cuir.car.chula.ac.th/handle/123456789/75131-
dc.descriptionThesis (M.Sc.)--Chulalongkorn University, 2006en_US
dc.description.abstractThis thesis demonstrates the fast and simultaneous detection of prominent heavy metals including lead, cadmium and cupper using a microchip capillary electrophoresis with electrochemical detection. Direct amperometric detection mode for microchip capillary electrophoresis was successfully applied to analytes, the heavy metal ions. The influences of the separation voltage, detection potential, concentration and pH value of running buffer on the response of the detector were carefully investigated and optimized. The zone electrophoretic separation of lead, cadmium and copper is less than 3 min using a MES buffer and L-Histidine as background electrolyte (pH 7.0, 25 mM), employing 1.2 kV as the separation voltage and -0.8 V as the detection potential. The detection limits for Pb2+, Cd2+, and Cu2+ were 1.74, 0.73 and 0.13 μM (S/N = 3), respectively. The %RSD of peak current was < 6 % and the %RSD of migration times <2% for prolong operation. To demonstrate the potential and future role of microchip CE, a new route in the real sample analysis was presented. The results obtained allow the proposed microchip capillary electrophoresis 9 electrochemical detection as a real gateway to microanalysis in foods.en_US
dc.language.isoenen_US
dc.publisherChulalongkorn Universityen_US
dc.rightsChulalongkorn Universityen_US
dc.titleMicrochip capillary electrophoresis with amperometric detection for metal ion analysisen_US
dc.title.alternativeไมโครชิพคะพิลลารีอิเล็กโทรฟอริซิสร่วมกับการตรวจวัดแบบแอมเพอโรเมทรีสำหรับการวิเคราะห์ไอออนโลหะen_US
dc.typeThesisen_US
dc.degree.nameMaster of Scienceen_US
dc.degree.levelMaster's Degreeen_US
dc.degree.disciplineChemistryen_US
dc.degree.grantorChulalongkorn Universityen_US
Appears in Collections:Sci - Theses

Files in This Item:
File Description SizeFormat 
Sarawadee_ko_front_p.pdf1.15 MBAdobe PDFView/Open
Sarawadee_ko_ch1_p.pdf673.94 kBAdobe PDFView/Open
Sarawadee_ko_ch2_p.pdf1.75 MBAdobe PDFView/Open
Sarawadee_ko_ch3_p.pdf1.06 MBAdobe PDFView/Open
Sarawadee_ko_ch4_p.pdf2.31 MBAdobe PDFView/Open
Sarawadee_ko_ch5_p.pdf628.88 kBAdobe PDFView/Open
Sarawadee_ko_back_p.pdf991.37 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.